• The Aten NRGence PE6324G 0U 24 AC Outlets eco Intelligent PDU provides the ability to monitor the center's health environment via sensors. NRGence eco PDU offers real-time power measurement – allowing you to monitor the power status of devices attached to the PDUs, either at the PDU device or Bank level, from practically any location via a TCP/IP connection. It also offers comprehensive power analysis reports – providing precise measurements of current, voltage, power and watt-hour in a real-time Display. It supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power and easy setup and operation via a browser-based user interface. The Pe6324G has 1 x IEC 60309,  21 x IEC 320 C13 and 3 x IEC 320 C19 outlets. Data Sheet  
  • The Aten PE7208G 1U eco PDUis an  intelligent PDU that contains  8 AC outlets and is available in various IEC socket configuration. They provide secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors. It supports outlet level power metering and monitoring and 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS as well as current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting. Data Sheet  
  • Aten PE7208G eco PDU offers remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDU, either at the PDU device or outlet level, from practically any location via a TCP/IP connection. The PE7208G supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoringCurrent, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting. It features 1 x IEC 320 C20, 7 x C13 and 1 x C19. Data Sheet
  • The Aten NRGence PE7214 1U eco PDUs are intelligent PDUs that contain 14 AC outlets and are available in various IEC socket configurations, supports 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS as well as PDU and outlet level power metering and monitoring. PE7214G also supports current, voltage, power, power dissipation, temperature, and humidity metering, threshold level setting and door sensor. Data Sheet Manual
  • Aten PE7328G NRGence 0U 28 Outlets Intelligent  eco PDU provide a secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center's health environment via sensors. The PDU offers remote power control combined with real-time power measurement — allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device, bank, or outlet level, depending on the model, from practically any location via a TCP/IP connection. Input connection is 1 x IEC 60309 and outlet types are: 24 x IEC320 C13 + 4 x IEC320 C19 Bank1-1 : Outlet 1 – 14 ; 12 x C13 + 2 x C19 Bank1-2 : Outlet 15 – 22 ; 7 x C13 + 1 x C19 Data Sheet
  • Aten PE8108G 8 Outlets eco PDU allows you to control and monitor the power status of devices attached to the PDUs at outlet level from practically any location via a TCP/IP connection. It features space saving 1U rack mount design with rear mounting, power-on sequencing  where users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order, and LED indicators for current and IP address at Outlet levels. It offers two-level password securit with strong security features that include password protection and advanced encryption technologies – 128 bit SSL  Input is 1 x IEC 320 C20 and 8 x IEC 320 C13 outlets. Data Sheet
  • Aten PE8208G 1U 8 Outlets Intelligent eco PDUoffers remote power control combined with real-time power measurement - allowing you to control and monitor the power status of devices attached to the PDUs, either at the PDU device or outlet level, from practically any location via a TCP/IP connection. It features separate power for the unit's own power and its power outlets. The user interface is still accessible even when an overload condition trips the devices' circuit breaker and has user outlet access assignment on an outlet-by-outlet basis. PE8208G has 1 x IEC320 C20 input, 7 x IEC 320 C13 and 1 x C19 outlets. Data Sheet ecoPDU-Telnet-Guide-w_2016-01-14.pdf (141.05 KB) pe snmp-s_2012-07-19.pdf (1.27 MB) pe6108-8208-eco-pdu-w_2015-12-09.pdf (2.18 MB)
  • The Aten NRGence PE8216G eco PDU is an intelligent PDU that contains 16 AC outlets and is available in various IEC socket configurations. Models in the advanced PE8 ranges feature NRGence´s proactive overload protection, which automatically powers off the last outlet that caused the current overload. It offers PDU and outlet level power metering and monitoring, current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting and supports door sensor. Input is 1 x IEC 60309 C20 and the outputs are: Total : 14 x IEC320 C13 + 2 x IEC320 C19 Bank1-1 : Outlet 1 – 8 ; 7 x C13 + 1 x C19 Bank1-2 : Outlet 9 – 16 ; 7 x C13 + 1 x C19 Data Sheet
  • The Aten NRGence PE8324G 0U eco PDU is an intelligent PDU that contains 24 AC outlets and provide secure, centralized, intelligent, power management (power on, off, cycle) of data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.), as well as the ability to monitor the center´s health environment via sensors. The power status of each outlet can be set individually, allowing users to switch each device On/Off. Input connection is IEC 60309 32A and outlets are: Total : 21 x IEC320 C13 + 3 x IEC320 C19 Bank1-1 : Outlet 1 – 8 ; 7 x C13 + 1 x C19 Bank1-2 : Outlet 9 – 16 ; 7 x C13 + 1 x C19 Bank2 : Outlet 17 – 24 ; 7 x C13 + 1 x C19 Data Sheet
  • Aten NRGence PE9330G eco PDU offer remote power control combined with real-time power measurement  The power status of each outlet can be set individually, allowing users to switch each device On/Off. It also offers comprehensive power analysis reports which can separate departments and locations, providing precise measurements of current, voltage, power and watt-hour in a real-time display. Installation and operation of the PE9330 is fast and easy: plugging cables into their appropriate ports and user-friendly browser-based configuration and management is all that is entailed. Since the eco PDU firmware is upgradeable over the Net, you can stay current with the latest functionality improvements simply by downloading updates from the manufacturer's  website as they become available. PE9330 input connection is 1 x IEC 60309 32A. The Outlets are: Total : 26 x IEC320 C13 + 4 x IEC320 C19 Bank1-1 : Outlet 1 – 14 ; 12 x C13 + 2 x C19 Bank1-2 : Outlet 15 – 22 ; 7 x C13 + 1 x C19 Bank2 : Outlet 23 – 30 ; 7 x C13 + 1 x C19 Data Sheet Manual
  • Adder ePower PSU-1GUARD enables the remote power control of one device over the Internet, Intranet, or locally through a serial RS232 connection. It features two password levels plus various administrator/user rights and security masks give IP security and the restart delay can be chosen between 5 and 60 seconds between off/on for activity at all power outlets. Data Sheet Manual
  • Adder PSU-8SLAVE ePower distribution unit can be used only with the Adder KVM Over IP products and it is not compatible with any other manufacturer.  It features two separate power inputs to improve security and increase total current load. Built-in serial interface allows easy control using simple ASC11 commands (can be used by any server or KVM switch to individually control the 8 power outlets. Data Sheet Manual